Download Print this page

Hitachi SJ-PB2 Instruction Manual page 39

Profibus-dp communication board for sj700/sj300/l300p series inverter

Advertisement

Code PNU Size
A043
86
2
A243
87
2
A343
88
2
A052
89
2
A055
90
2
A058
91
2
A064
92
2
A066
93
2
A068
94
2
A070
95
2
A073
96
2
A074
97
2
A075
98
2
A086
99
2
b003
101
2
b012
102
2
b212
103
2
b312
104
2
b015
105
2
b016
106
2
0 – "Rated Current" (max:2000.0A)
b017
107
2
b018
108
2
0 – "Rated Current" (max:2000.0A)
b019
109
2
b020
110
2
0 – "Rated Current" (max:2000.0A)
b100
111
2
"Free-setting, V/f frequency 2" Hz
b101
112
2
b102
113
2
"Free-setting, V/f frequency 3" Hz
b103
114
2
b104
115
2
"Free-setting, V/f frequency 4" Hz
b105
116
2
b106
117
2
"Free-setting, V/f frequency 5" Hz
b107
118
2
b108
119
2
"Free-setting, V/f frequency 6" Hz
b109
120
2
b110
121
2
"Free-setting, V/f frequency 7" Hz
b111
122
2
b112
123
2
b113
124
2
b022
125
2
20.0 - 180.0% (75~132KW)
b023
126
2
b025
127
2
20.0 - 180.0% (75~132KW)
b026
128
2
Range
0 - 50.0%
0 - 50.0%
0 - 50.0%
0 - 400.00Hz
0 - 60.0s
0 - 60.0s
0 - 10.00Hz
0 - 10.00Hz
0 - 10.00Hz
0 - 60.0s
0 - 3600.0s
0 - 100.00
0.01 - 99.99%
0 - 100.0
0.3 - 100.0s
20.0 - 100.0%
20.0 - 100.0%
20.0 - 100.0%
0 - 400Hz
0 – 400Hz
0 - 400Hz
0 –
0.0 - 800.0V
0 –
0.0 - 800.0V
0 –
0.0 - 800.0V
0 –
0.0 - 800.0V
0 –
0.0 - 800.0V
0 –
0.0 - 800.0V
0 - 400Hz
0.0 - 800.0V
20.0 - 200.0% (~55KW)
0.10 - 30.00
20.0 - 200.0% (~55KW)
0.10 - 30.00
APPENDIX PARAMETER OBJECT LISTS
Magn.
*10
1st Break point
*10
2nd Break point of manual torque boost
*10
3rd Break point of manual torque boost
*100
Frequency of DC braking start
*10
Time of DC braking working
Time of DC braking working for beginning of
*10
inverter running
*100
Width of jumping frequency 1
*100
Width of jumping frequency 2
*100
Width of jumping frequency 3
*10
Time of stopping to accelerate
*10
Integrate (I) gain of PID control
*100
Differential (D) gain of PID control
*100
Scale of PID control
*10
Response time of Energy saving function
*10
Waiting time of retry
*10
Level of 1st Electronic thermal protection
*10
Level of 2nd Electronic thermal protection
*10
Level of 3rd Electronic thermal protection
*1
Free electronic thermal frequency 1
*10
Free electronic thermal current 1
*1
Free electronic thermal frequency 2
*10
Free electronic thermal current 2
*1
Free electronic thermal frequency 3
*10
Free electronic thermal current 3
*1
Free V/F control frequency 1
*10
Free V/F control voltage 1
*1
Free V/F control frequency 2
*10
Free V/F control voltage 2
*1
Free V/F control frequency 3
*10
Free V/F control voltage 3
*1
Free V/F control frequency 4
*10
Free V/F control voltage 4
*1
Free V/F control frequency 5
*10
Free V/F control voltage 5
*1
Free V/F control frequency 6
*10
Free V/F control voltage 6
*1
Free V/F control frequency 7
*10
Free V/F control voltage 7
*10
Level of Overload restriction 1
*100
Constant value of Overload restriction 1
*10
Level of Overload restriction 2
*100
Constant value of Overload restriction 2
35
Contents
of manual torque boost
Read/
Write
R/W
R/W
R/W
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/W
R/W
R/WOS
R/W
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS

Advertisement