Information On Protection Class And Degree Of Protection - Siemens SIMATIC IFP1200 Basic Operating Instructions Manual

Hide thumbs Also See for SIMATIC IFP1200 Basic:
Table of Contents

Advertisement

Radiated emission (emitted interference)
1 GHz to 3 GHz
3 GHz to 6 GHz
30 MHz to 230 MHz
230 MHz to 1000 MHz
Emission of radio interference voltages
0.150 MHz to 0.5 MHz
0.5 MHz to 30 MHz
7.5.2.4

Information on protection class and degree of protection

Protection class
Protection Class III in accordance with IEC 61010-1, for example. with protective conductor.
Protection against foreign objects and water
For the device IFP Basic, the information on degree of protection is as follows:
Degree of protec-
tion
Front
Rear
1
2
The degree of protection for the device IFP1200 Basic C is as follows:
• IP65 according to IEC 60529
Degree of pollution and overvoltage category
The device IFP Basic and IFP Basic C meets the following requirements according to IEC/UL
61010-2-201:
Degree of pollution
Overvoltage category
IFP Basic
Operating Instructions, 06/2023, A5E46178354 - AD
Explanation
When mounted:
IP65 according to IEC 60529
IP40 for IFP1200 Basic, IFP1500 Basic, IFP1900 Basic
IP20 for IFP2200 Basic
The degree of protection of the front panel can only be guaranteed if the mounting seal
is properly installed at the cabinet.
The degree of protection of the rear panel can only be guaranteed when all the interface
are plugged in.
< 76 dB peak and < 56 dB average
< 80 dB peak and < 60 dB average
< 40 dB (μV/m) quasi-peak
< 47 dB (μV/m) quasi-peak
< 79 dB quasi-peak and < 66 dB average
< 73 dB quasi-peak and < 60 dB average
1
2
2
II
Technical information
7.5 Technical specifications
2
73