Fujitsu D2509 Technical Manual page 23

System board
Table of Contents

Advertisement

Features
The LEDs have the following meaning:
LED
A - Identification blue
B - CSS
(Customer Self
Service)
C - GEL
(Global Error
LED)
D1 - board
D2 - board
D3 - board
D4 - board
E - memory
F - system
fans
G - CPU fans
H - PCI card
D2509 (TX200 S4)
Indicator
Meaning
server is identified via ServerView
yellow
indicates a prefailure
yellow flashing indicates a failure
orange
indicates a prefailure
orange flashing indicates a failure. Reasons for a failure
may be:
- overheating of one of the sensors
- sensor defect
- fan defect
- CPU error
- Software detected an error
yellow
aux. voltage available
green
system running
red
configuration error. The system board will
be held in reset.
Possible configuration errors are e.g.: old
CPU populated, CPUs with different FSB
requirements populated, CPU1 not
populated
green flashing
iRMC - server management controller is
ok
off
iRMC not alive
off
memory module running
orange
memory module failure
off
fan running
orange
fan failure
off
fan running
orange
fan failure
off
PCI card okay
orange
PCI card failure
Technical Manual