2.
Connect the compressed-air supply to the
scissors lift table.
The compressed-air connection has a 1/4 inch
external thread.
Use clean and dry compressed air with a
pneumatic input pressure only up to 6 bar
(87.02 psi).
Figure 7:
Connecting the Compressed-Air Supply
7
Bottom Frame
9
Pedal (end marked "RELEASE")
10
Pump
11
Pedal (end marked "PUMP")
12
Brake Pedal
15
Hydraulic Pressure Relief Valve
16
Compressed-Air Connection
19
Ball Valve
20
Manometer Connection
3.
If necessary, unlock the padlock on the ball valve
(19). Twist the ball valve (19) until it is parallel to
the bottom frame (7) to release the platforms (3)
and (4).
4.
Press the end of the pedal marked "PUMP" (11)
to raise the platforms (3) and (4).
The pedal may briefly vibrate when pressed. This
is normal and presents no danger.
5.
Press the lever (2) to release the mechanical lock
(17). Simultaneously press the end of the pedal
marked "RELEASE" (9) to lower the platforms (3)
and (4).
SP04006297 | 06/2021
2.3.5

Ball Valve and Padlock

The lockable ball valve (19) with the padlock protects
the scissors lift table from being used by unauthorised
persons.