Source
ID
Timing when an event is logged
Windows Server 2016
icea
262
When SFP+/SFP28 module(N8104-189/190)
or DA cable disconnected from optional LAN
board(N8104-208/212).
icea
272
When SFP+/SFP28 module (N8104-189/
190) or DA cable is connected to the LAN
board (N8104-208/212) and the network link
is down.
Applying Standard Program Package.
icea
1284
When installing an OS, starting system, or
applying Standard Program Package
Service Control Manager
7023
When running an OS for the first time
Level
"System Log"
Error
Error
Error
Error
Installation Guide (Windows Server 2016)
Message (Description)
Action
Intel(R) Ethernet Network Adapter E810-XXV-2 xxx
PROBLEM: Module is not present.
Possible Solution(s):
Manually set the speed/duplex or use Intel(R) Ethernet Port
Configuration Tool to change the port option.
If the problem persists, use a cable/module that is found in the
supported modules and cables list for this device.
* "x" depends on the optional LAN board environment.
Confirm the SFP+/SFP28 module (N8104-189/190) or DA cable.
Intel(R) Ethernet Network Adapter E810-XXV-2 xxx
PROBLEM: A parallel fault was detected.
Possible Solution: Change link partner connection and configuration.
* x is a different display name depending on the LAN board.
This event does not affect system operation.
But, this event may be registered in large numbers, and this can be
suppress in the following method:
-
Avoid intentionally disconnecting cables
-
Do not mount the SFP+/SFP28 module (N8104-189/190) in
unused slots
-
Do not connect DA cable with unconnected opposite side
Intel(R) Ethernet Network Adapter E810-XXV-2 xxx
PROBLEM: DDP package failed.
Possible Solution: Update to latest base driver and DDP package.
* x is a different display name depending on the LAN board.
This event does not affect system operation.
"xxxxxxxx service terminated with the following error:
A device attached to the system is not functioning."
This event does not affect system operation if it is recorded only on
the first startup and not recorded repeatedly.