WARNING!
The inlet water shall not
exceed 25 °C.
Water drainage
The drain hose should stay at a height of
no less than 60 cm and not more than
100 cm.
You can extend the drain
hose to maximum 400 cm.
Contact the authorised
service centre for the other
drain hose and the
extension.
It is possible to connect the drain hose in
different ways:
1. The drain hose can be bent into U
shape and put around the plastic guide.
Buy accessories from
authorised supplier.
On the edge of a sink - Fasten the guide
to the water tap or to the wall.
Make sure that the plastic
guide cannot move when the
appliance drains and the
drain hose end is not
immersed in the water.
There may be a return of
dirty water into the
appliance.
2. If the end of the drain hose looks like
this (see the picture), you can push it
directly into the stand pipe.
3. To a stand pipe with vent hole - Insert
the drain hose directly into a drain pipe.
Refer to the illustration.
The end of the drain hose
must always be ventilated ,
i.e. the inner diameter of the
drain pipe (min. 38 mm -
min. 1.5") must be larger
than the external diameter of
the drain hose.
4. Without the plastic hose guide, to a
sink spigot- Put the drain hose in the
spigot and tighten it with a clamp. Refer
to the illustration.