MAINTENANCE PROCEDURE

CHANGE OIL IN SWING MACHINERY CASE

Parts and oil are at high temperature immediately after the engine is stopped and may cause serious burns. Wait for the oil
temperature to go down before performing this operation.
Refill capacity: 48.6 liters (12.84 US gal) (24.3 liters X 2 (6.42 US gal X 2))
1. Pull out drain hose (1) under the chassis from inspection
window (2).
2. Set a container under the drain hose to catch the drained oil.
3. Loosen drain valve (P) under the body, drain the oil, then
tighten the drain valve again.