Philips EJ3.0UPA Service Manual page 96

Table of Contents

Advertisement

EN 96
8.
EJ3.0U PA
Table 8-1 White D alignment values
Color Temp.
Cool
(degr. K)
(11500)
x
0.275
y
0.276
When such equipment is not available, use "method 2".
Method 2 (without color analyzer):
If you do not have a color analyzer, you can use the default
values. This is the next best solution. The default values are
average values coming from production (statistics).
1. Select a COLOUR TEMPERATURE (e.g. COOL,
NORMAL, or WARM).
2. Set the RED, GREEN and BLUE default values according
to the values in the "Tint settings" table.
3. When finished press STORE (in the SAM root menu) to
store the aligned values to the NVM.
4. Restore the initial picture settings after the alignments.
Table 8-2 Tint
Colour Temp.
R
Cool
122
Normal
125
Warm
127
Alignments
Normal
Warm
(9100)
(6500)
0.287
0.314
0.292
0.320
G
B
120
121
118
108
110
75