Philips EJ3.0UPA Service Manual page 98

Table of Contents

Advertisement

EN 98
8.
EJ3.0U PA
8.4.4
Option Numbers
Select this sub menu to set all options at once (expressed in
two long strings of numbers).
An option number (or "option byte") represents a number of
different options. When you change these numbers directly,
you can set all options very quickly. All options are controlled
via eight option numbers.
When the EAROM is replaced, all options will require resetting.
To be certain that the factory settings are reproduced exactly,
you must set both option number lines. You can find the correct
option numbers on a sticker inside the TV set.
CTN
Options Group 1
02064 00292 00549 02691 01049 00000 21152 00000
42PFP5332D/37
42PFP5342D/37
02064 00292 00549 02691 01108 00000 21152 00000
42PFP5332D/37
42PFP5342D/37
02064 00292 00549 02691 01109 00000 21152 00000
50PFP5332D/37
50PFP5342D/37
02064 00292 00549 02691 01110 00000 21152 00000
50PFP5332D/37
50PFP5342D/37
Group 1 indicates hardware options 1 to 4, Group 2 indicates
software options 5 to 8.
Every 5-digit number represents 16 bits (so the maximum value
will be 65536 if all options are set).
When all the correct options are set, the sum of the decimal
values of each Option Byte (OB) will give the option number.