FE HEAD ASSEMBLY/TAPE CLEANER ASSEMBLY REPLACEMENT
Toots :
Cleaning piece : 2-034-697-00
Cleaning fluid : 9-919-573-01
Replacement ftow chart
Removal
=
1. Unplug the connectors from the Tape End Sensor
harness (3 pins)
Assembly and the Full Erase Head Assembly.
(Only Tape End Sensor Assembly in UVW-1600P)
2,
Remove the screw holding the FE Head Assembly
or the Tape Cleaner Assembly. Remove the FE
FE Head Assembly/
g
Head Assembly or the Tape Cleaner Assembly
Tepe Cleaner Assembly
|
fxing sorew
from chassis.
AR WHS)
3,
Remove
the screw assembling the FE Head
Assembly or the Tape Cleaner Assembly. Remove
the FE Head or the Tape Cleaner Assembly from
their Assembly.
4,
Unsolder the connector (3 pins) from the Full
Erase Head. (UVW-1800P only)
Tape End
Sensor Ass'y
holes
Instaltation
5.
Solder the connector (3 pins) to a new Full Erase
Head. (UVW-1800P only)
6.
Clean the respective mounting surfaces with
cleaning piece moistened with cleaning fluid.
7.
Align the protrusion of the Full Erase Head or Tape
Cleaner Assembly,
with the groove on the
mounting surface, Push it in the direction of arrow
and assemble them.
8.
Align the boss of the FE Head Assembly or Tape
Cleaner Assembly, with the holes of the slant
chassis. Install it with a screw.
o-— connector (3 pins)
9.
.Connect the two harnesses to the Full Erase Head
and Tape End Sensor Assembly.
Tate Circe Asenbly
(Only Tape End Sensor Assembly in UVW-1600P)
Pinch Press Assembly
chassis assembly
Full Erase Head/
Tape Cleaner
protrusion
groove
fixing sorew
(PS2X4}