Installation
Creating the rear wall cut-out with flush-fit installation and an installation
depth of 23,8 cm
Ideally, the drilling template supplied with the appliance should be used. The fol-
lowing instructions should only be used if the drilling template is not available.
View of the drilling template side 1. Not to scale.
Measure the thickness of your worktop (C).
Locate the centre of the long axis of the cut-out.
Mark the point that is 183 mm (A) to the right of the midpoint.
Mark the point (D) that is (B [159.5 mm] – C [thickness of the worktop]) below the
right end of distance A.
Saw a hole with a diameter of 146–150 mm around this point.
Plug&Play mode only: engage the Plug&Play adapter in position 1.
103