RESTRICTED
P o s N a m e
1 1 I N D I R E C T b u t t o n
1 2 P L A I N b u t t o n
1 3 C O R R E C T I O N b u t t o n
1 4 D E C I b u t t o n
1 5 Ta p e p u n c h o n / o f f
Function
Two-position button for putting AROFLEX into the DIRECT or IN
DIRECT mode. The INDIRECT mode is selected by pushing the IN
DIRECT button and is indicated by the lit lamp. The mode of operation
must be selected before starting to encipher or decipher. When lit,
the lamp inside the INDIRECT button signifies "text in memory".
A change from INDIRECT to DIRECT or vice versa resets the memory
and extinguishes the lamp.
Two-position button for putting AROFLEX into the PLAIN text mode,
indicated by lit lamp and depressed button.
Pushing and releasing the PLAIN button clears message memory.
Spring-loaded pushbutton for character-by-character correction of:
— input in the INDIRECT DECI mode
— input in the INDIRECT ENCI mode
— input for paging information
— typed-in manual message key (see paragraph 7.4 and Figure 2)
The lamp inside this button has 3 functions:
— steady burning in the DECI mode indicates incorrect format
— slow blinking + procedure signal in the DECI mode after the
11th group indicates the "no key" condition
— fast blinking + procedure signal in any mode indicates a SPECAT
condition: the SPECAT key (22) must be inserted and turned before
the operation (keysetting, enciphering or deciphering) can proceed,
using key compartment X or Y.
Two-position pushbutton for selecting the deciphering function,
indicated by lit lamp.
Spring-loaded pushbutton for switching the tape punch on and off;
lit lamp inside the button indicates that the punch is switched on.
In the line-connected mode this control is overruled by the depressed
PUNCH STANDBY button(6).