RESTRICTED
23
12. Push the OUT button (3)
to put AROFLEX into
the standby mode.
Lamp inside OFF-LINE button is
extinguished.
4.5.3 Enciphering:
INDIRECT mode
1. Carry out crypto procedure
(see 4.5.1.)
2. Push INDIRECT button
Lamp lights inside button .
NOTE
Omit Steps 3, 4 and 5 if plain-text heading is not required.
3. Type Format Lines 1 ... 4 AROFLEX prints text as typed
(see also Step 4) and stores in memory.
NOTE
Format Lines 1 ... 4 are not counted for ACP-127 paging format.
4. Press PREAMBLE button (8) Lamp in button lights; lamp in
after typing CR-LF at end PROC button is extinguished.
of Line 4.
5. Type Format Lines 5 ... 11 AROFLEX prints text as typed
and stores in memory.
NOTES
(1) In the PREAMBLE mode, Line Feeds are counted for ACP-
127 paging procedure, to form a first page of 20 lines.
(2) Redundant Figures/Letters shifts are disregarded.
(3) Format Line 10 cannot be entered as the group count is
not yet known.
RESTRICTED