Bosch AUTODOME 7100i Installation Manual page 65

Hide thumbs Also See for AUTODOME 7100i:
Table of Contents

Advertisement

AUTODOME 7100i│AUTODOME 7100i IR
Warning!
Make sure that you connect the outgoing power supply wires to the appropriate pins as
!
described. Power supply fuse XF103 can handle a higher amperage (3.15 A) than fuse
XF102 (2.0A).
6.
7.
8.
9.
10. Route the Ethernet cable through the points mentioned in the list that follows, in
Bosch Security Systems
Connect the first wire to pin 5 (24VAC Neutral) connector.
Connect the second wire to pin 4 (24VAC Line) connector. (Note: the 3.15A fuse is in
this line.)
Connect the third wire to pin 3 (Earth Ground) connector.
For the AUTODOME 7100i non-IR model (NDP-7602-Z40) only, complete the three sub
steps that follow, and then proceed to further steps. For IR models, skip to the next
step.
a. Route the 24 VAC outgoing power supply wires through a conduit hole to electrically
grounded conduit, through a mount that supports grounded conduit (like NDA-U-WMP)
to the pipe mount and to the camera, or through the Arm Mount and WPLATE to the
camera.
b. Cut and trim the 24 VAC power with sufficient slack to reach their connector
terminal X105 in the camera, but not so long as to be pinched by or to obstruct closing
the cover door.
c. Attach the 24VAC lines to AUTODOME 7100i User Interface connector X105, as
illustrated below.
Note: Use of proper grommets is necessary to guarantee an IP66 rating.
Note: Refer to Tools Required, page 14 for a list of the appropriate types of Ethernet
cable to use.
sequence:
a. From the User Interface connector X104 in the pipe or ARM mount (as shown below)
b. Into a 3/4 in. (20mm) NPS metal conduit fitting in the NDA-U-WMP (for instance)
when using a pipe mount or in the WPLATE when using the arm mount.
c. Through electrically grounded, liquid tight metal conduit
d. To a 3/4 in. (20mm) NPS metal conduit fitting in the PSU box, and
e Out another 3/4 in. (20mm) NPS metal conduit fitting in the PSU box
f. Through electrically grounded, liquid tight metal conduit
Installation Manual
Connection | en
2023-09-29 | V06 | F.01U.410.315
65