.MAINTENANCE PROCEDURE
When it is impossible to check electrolyte level from
side of battery
If it is impossible to check the electrolyte level from the side of the battery, or there is no display of the UPPER
LEVEL line on the side of the battery, check as follows.
1. Remove cap (1) at the top of the battery, look through the
water filler port, and check the electrolyte surface. If the
electrolyte does not reach the sleeve, add distilled water so
that the level reaches the bottom of the sleeve (UPPER
LEVEL line) without fail.
Use the diagram below for reference, and check if the electrolyte reaches the bottom of the sleeve.
Correct level
The electrolyte level is up to the bottom of the
A
sleeve, so the surface tension causes the surface
to rise and the plate appears to be warped.
Too low (level)
B
The electrolyte level is not up to the bottom of the
sleeve, so the plate appears to be normal.
2. After adding distilled water, tighten cap (1) securely.
REMARK
If distilled water is added to above the bottom of the sleeve, use a pipette to lower the level to the bottom
of the sleeve. Neutralize the removed fluid with baking soda (sodium bicarbonate), then flush it away with
a large amount of water or consult your Komatsu distributor or battery maker.
When it is possible to use indicator to check electrolyte level
If it is possible to use and indicator to check the electrolyte level, follow the instructions given.
CHECK AIR CONDITIONER COMPRESSOR
BELT TENSION, ADJUST
Checking
1. Remove radiator fan guard (A).