.MAINTENANCE PROCEDURE
2. Open cover (2) at the bottom left of the operator's cab by
hand, pull out filter case (3) from the inside, then remove the
filter.
3. Clean the filter with compressed air. If there is oil on the filter, or if the filter is extremely dirty, wash it in a neu-
tral agent. After rinsing it in water, dry it thoroughly before using it again.
If the clogging of the filter cannot be removed by blowing with air or washing in water, replace the filter with a
new part.
4. After cleaning, insert the filter in filter case (3) again, open the cover at the bottom left of the operator's cab by
hand, return the filter case to its original position, then close the cover. When doing this, check that the lock is
applied.
REPLACE BREATHER ELEMENT IN HYDRAULIC TANK
When the oil filler cap is removed, oil may spurt out, so turn the cap slowly to release the pressure before
removing the cap.
1. Remove the cap of oil filler (F) at the top of the hydraulic
tank.
2. Replace element (1) inside the cap.
4-50
WARNING
MAINTENANCE
0.