MAINTENANCE PROCEDURE

REPLACE BREATHER FILTER ELEMENT IN HYDRAULIC TANK

After the engine is stopped, the parts and oil are at high temperature, so there is danger of burns. Wait for the temperature to
go down before starting the operation.
When removing the cap from oil filler port (F), turn it slowly to release the internal pressure, then remove it carefully.
1. Remove the cap of oil filler (F) at the top of the hydraulic tank.
2. Replace element (1) inside the cap.