Lubricate Swing Circle - Komatsu PC600-6 Operation And Maintenance Manual

Hydraulic excavator
Table of Contents

Advertisement

MAINTENANCE
Use the diagram below for reference, and check if the electrolyte reaches the bottom of the sleeve.
2. After adding distilled water, tighten cap (1) securely.
REMARK
If distilled water is added to above the bottom of the sleeve, use a syringe to lower the level to the bottom of the
sleeve. Neutralize the removed fluid with baking soda (sodium bicarbonate), then flush it away with a large amount
of water or consult your Komatsu distributor or battery maker.
When it is Possible to Use Indicator to Check Electrolyte Level
If it is possible to use and indicator to check the electrolyte level, follow the instructions given.

LUBRICATE SWING CIRCLE

(3 places)
1. Lower the work equipment to the ground.
2. Using a grease gun, pump in grease through the grease fittings
shown by arrows.
3. After greasing, wipe off all the old grease that was pushed out.
MAINTENANCE PROCEDURE
4 - 47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc600lc-6

Table of Contents