Download Print this page

ABB TL Series Installation Manual

Advertisement

Quick Links

T W I L I G HT SW I TC H
TL LINE
Installation manual
Disclaimer
The information in this document is subject to change without notice and should not be construed
as a commitment by ABB Spa. ABB Spa assumes no responsibility for any errors that may appear in
this document.
In no event shall ABB Spa be liable for direct, indirect, special, incidental or consequential damages
of any nature or kind arising from the use of this document, nor shall ABB Spa be liable for
incidental or consequential damages arising from use of any software or hardware described in
this document.
Copyrights
This document and parts thereof must not be reproduced or copied without written permission
from ABB Spa, and the contents thereof must not be imparted to a third party nor used for any
unauthorized purpose.
The software or hardware described in this document is furnished under a license and may be
used, copied, or disclosed only in accordance with the terms of such license.
© Copyright 2020 ABB Spa. All rights reserved.
Trademarks
ABB Spa is a registered trademark of the ABB Group. All other brand or product names mentioned
in this document may be trademarks or registered trademarks of their respective holders.
Contact
ABB SpA
Via Dell'industria, 18
20010 – Vittuone – Milano
Italy
Tel. +39 02 2415 0000
TL1, TL1 Pole, TLS
Installation Manual
Document ID: 9AKK107991A3020
Revision: A
2020-10-13
1 /4

Advertisement

loading

Summary of Contents for ABB TL Series

  • Page 1 In no event shall ABB Spa be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, nor shall ABB Spa be liable for incidental or consequential damages arising from use of any software or hardware described in this document.
  • Page 2 Safety warning The device must always be protected on the incoming side by fuse or circuit breaker with a max nominal current of 16A 1. Mounting Instruction TL1 + TLs (peripherical device) Tightening torque Important notice After installation the cable coming out from the device must be fixed re- liably.
  • Page 3 Technical data TL1 Pole Rated supply voltage 110 ÷ 230 AC Contact type 1NO polarized Incandescent lamps 110 V 1000 230V 1000 LED/CFL – externally ballasted 110 V 230V LEDi/CFLi – self ballasted 110 V 230V Rated frequency 50/60 Switching delay ON 23+-10% 25+-10% Switching delay OFF...
  • Page 4 TL1 Pole Max terminal cross section Terminals loss-proof screw Screw Type Tightening torque: terminals Tightening torque: screw sensor Mounting on DIN Rail Pole/wall mounted Switching status indication /brightness range red/green LEDs Max wiring length Max wiring width 1000w all other sensor 0,75 Modules...

This manual is also suitable for:

Tl1Tl1 poleTls