Mitsubishi Electric AE-50A Instruction Book page 73

Hide thumbs Also See for AE-50A:
Table of Contents

Advertisement

Item
Energy management
data
WT07139X02
[Data type: 1-day intervals]
Row
Item
1st
File Type
2nd
Data range
*1
3rd
Item
*2*3*4
Measurement
4th
unit
*2*6*7*8
5th–
Data
779th
*2*3*4*9*10*11*12
*1 The date will appear in the format that has been set on the Basic System settings screen, accessible
via the Web Browser for Initial Settings.
*2 The separator character and decimal point character selected on the Measurement screen
(accessible via the Web Browser for Initial Settings) will be used to the data.
*3 The numbers shown after "MCP" and "MCT" indicate channel No.
*4 The numbers in the parentheses indicate M-NET addresses.
*5 The M-NET address indicated in the parentheses will not appear for the measurement data of the
built-in PI controller.
*6 The temperature unit °C or °F will appear, depending on the temperature unit that has been selected
on the Basic System settings screen, accessible via the Web Browser for Initial Settings.
*7 The measurement unit for MCP (PI controller) will be the measurement unit that has been set on the
Measurement screen, accessible via the Web Browser for Initial Settings.
*8 The measurement item for MCT (AI controller) will be temperature or humidity, which has been set
on the Measurement screen, accessible via the Web Browser for Initial Settings.
*9 "Outdoor temperature," "Cooling set temperature," "Heating set temperature," and "Room
temperature" in the data are the average daily values of the temperature values obtained every hour.
*10 "MCT 1" and "MCT 2" in the data are the average daily temperature or humidity values obtained
every hour.
*11 The value will not appear if the data does not exist.
*12 Each file contains up to 775 data (25-month worth of data).
Description
503
Start date + "–" + End date
"Date,Data1(51),...Data1(100),Data3(51),...Data3(100),
OutdoorTemp(51),...OutdoorTemp(100),CoolSetTemp(1),...CoolSetTemp(50),
HeatSetTemp(1),...HeatSetTemp(50),RoomTemp(1),...RoomTemp(50),
FanTime(1),...FanTime(50),CoolTime(1),...CoolTime(50),
HeatTime(1),...HeatTime(50),ThermoTime(1),...ThermoTime(50),
CoolThermoTime(1),...CoolThermoTime(50),
HeatThermoTime(1),...HeatThermoTime(50),
SaveValue(1),...SaveValue(50),CoolSaveValue(1),...CoolSaveValue(50),
HeatSaveValue(1),...HeatSaveValue(50),
ApporionedElectricEnergy(1),...ApporionedElectricEnergy(50),
TargetElectricEnergy(1),...TargetElectricEnergy(50),
MCP1(0),...MCP1(50),MCP2(0),...MCP2(50),MCP3(0),...MCP3(50),
MCP4(0),...MCP4(50),MCT1(1),...MCT1(50),MCT2(1),...MCT2(50),
AHC1(201),...AHC1(250),AHC2(201),...AHC2(250),
*5
MCP1,MCP2,MCP3,MCP4
"
Item
ApportionedElectricEnergy, TargetElectricEnergy
Data1, Data3
OutdoorTemp, CoolSetTemp, HeatSetTemp,
RoomTemp
FanTime, CoolTime, HeatTime, ThermoTime,
CoolThermoTime, HeatThermoTime, SaveValue,
CoolSaveValue, HeatSaveValue
MCP (PI controller/Built-in PI controller)
MCT (AI controller)
AHC (Advanced HVAC CONTROLLER)
*1
Date
, Data 1 (51), ... (100), Data 3 (51), ... (100),
Outdoor temperature (51), ... (100), Cooling set temperature (1), ... (50),
Heating set temperature (1), ... (50), Room temperature (1), ... (50),
Fan operation time (1), ... (50), Cooling operation time (1), ... (50),
Heating operation time (1), ... (50), Thermo-ON time (1), ... (50),
Cooling Thermo-ON time (1), ... (50), Heating Thermo-ON time (1), ... (50),
Capacity-save value (1), ... (50), Cooling capacity-save value (1), ... (50),
Heating capacity-save value (1), ... (50), Apporioned electric energy (1), ... (50),
Target electric energy (1), ... (50), MCP 1 (1), ... (50), MCP 2 (1), ... (50),
MCP 3 (1), ... (50), MCP 4 (1), ... (50), MCT 1 (1), ... (50), MCT 2 (1), ... (50),
AHC temperature 1 (201), ... (250), AHC temperature 2 (201), ... (250), MCP 1,
MCP 2, MCP 3, MCP 4
73
Format
Unit
kWh
-
ºC, ºF
Minute
kWh, m3, MJ
ºC, ºF, %
ºC, ºF