No.
Item
Optional Function
12
bC
Not used
13
bd
Not used
14
bE
Not used
15
C1
Not used
16
C2
Not used
17
C3
Not used
18
C4
Not used
19
C5
Static pressure sel. / Increase Fan Hi speed
20
C6
Increase of fan speed at heating Thermo-OFF
21
C7
Cancel 3 min. compressor starting delay
22
C8
Sensor selection for indoor temp. control
23
C9
Not used
24
CA
Not used
25
Cb
Selection of forced stoppage logic
Individual
Setting
Setting
Condition
00
00
-
01
01
00
00
-
01
01
00
00
-
01
01
00
00
-
01
01
-
-
Not Used(Use as 00 setting conditions)
00
00
-
01
01
00
00
-
01
01
00
Standard static pressure/ Standard speed
○
01
High static pressure/ Hi speed 1(*5)
02
Low static pressure/ Hi speed 2
00
Unavailable
○
01
Available
00
Standard
○
01
Cancellation
00
Indoor air suction sensor/ average air suction-
01
THM4
○
02
Wired controller sensor/ THM4(remote sensor)
Average return air sensor and (controller
sensor or remote sensor)
-
-
Not Used(Use as 00 setting conditions)
-
-
Not Used(Use as 00 setting conditions)
00
Normally Open
○
01
Normally Closed
5. Function Selection
Contents
Setting
16