Siemens SINUMERIK 840D sl Equipment Manual page 107

Handheld terminal
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Note
Use this terminal for simple routing of the emergency stop cables, optional.
The connector is only used to assist looping through. The connected pins 1 and 2 as well as 3 and
4 have no additional function on the connection module.
X20: Enabling buttons
Connector designa‐
tion:
Connector type:
Table 7-3
X21: Emergency Stop and key-operated switch
Connector designa‐
tion:
Connector type:
Table 7-4
Handheld Terminal HT 8
Equipment Manual, 02/2024, A5E52918633B AA
Pin
3
4
X20
8-pin Phoenix terminal
Assignment of the interface enabling buttons X20
Pin
Signal name
1
ZUST1P
2
ZUST1M
3
ZUST2P
4
ZUST2M
5
N.C.
6
N.C.
7
N.C.
8
N.C.
X21
10-pin Phoenix terminal
Assignment of the interface Emergency Stop and Module Supply Voltage
Pin
Signal name
1
STOP23
2
STOP24
3
STOP13
4
STOP14
5
M
6
N.C.
Protective circuit
On-board jumper
between 3 and 4
Signal type
I
Electronic enabling button 1 P
O
Electronic enabling button 1 M
I
Electronic enabling button 2 P
O
Electronic enabling button 2 M
-
-
-
-
Signal type
 
B
P
-
Connecting
7.3 PN Basic connection module
Meaning
Not connected
Not connected
Not connected
Not connected
Meaning
Emergency Stop circuit
Emergency Stop circuit
Emergency Stop circuit
Emergency Stop circuit
Ground
-
107

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents