"Modify settings for operator panel (TCU)" dialog
The following dialog appears when "Modify settings" is selected from the main menu:
Figure 4-12
The central area is for setting the TCU parameters:
• "HT 8 individual mode" (yes/no)
This is only visible with HT 8, and is used to switch between Auto Mode and Individual Mode.
There is no need to make any settings if an HT 8 is in Auto Mode, as the name is determined
automatically: ("DIP<n>") the MCP address and TCU index are determined by the DIP setting
("DIP<n>").
It is possible, however, that another device is registered for the name selected. Such
situations may only prove to be temporary, as is the case when DIP settings or two HT 8 have
been confused. For this reason, this status is not reported as an error immediately, but
identified as a possible problem instead ("potential name/DIP setting collision"). The text will
only read ("Name/DIP settings collision") if the situation remains unchanged after some time
has elapsed.
The process itself is unaffected, as the changes only relate to how the warning or error is
displayed. The explanatory text informs the user that they have probably assigned the same
DIP number twice and suggests they change one of them before rebooting the HT 8.
• "Operator panel index - TCU" (0-255)"
This specifies the TCU index. It matches the [Station] tcuIndex setting from the config.ini file.
• "Machine control panel address - MCP" (0-255)
This specifies the address of the associated MCP. It matches the [Station] mcpIndex setting
from config.ini.
Handheld Terminal HT 8
Equipment Manual, 02/2024, A5E52918633B AA
TCU menu: Settings
General information and networking
4.3 Networking
51