[433CMX/433MXE]
Special Installation (Place product upright and flush into wall (embedding in the wall))
(2) Embedding in walls with no space provided behind the unit.
Attach this fan on the
left side
Panting (Punching) net
(numerical aperture 50% or
over)
Cation : Due to possible heat up, we do not recommend installation in narrow, enclosed areas.
✩ Operating Temperature Restrictions
• Ambient temperature: 0 to 35 °C
Methods of Securing: Basic methods of securing are shown below. Avoid blocking or covering areas aside from those
indicated by
Before attaching the unit to fittings, double-check that the thickness and height of the fittings,
and the number of fixing bolts is correct.
(Also refer to 3.6.1 "Mounting to fittings".)
100mm or
more
. The methods indicated by a large X-mark must not be used.
100mm or
more
50mm or
more
65