Dell 8 Owner's Manual page 121

Poweredge modular systems
Hide thumbs Also See for 8:
Table of Contents

Advertisement

Table 1-26. Blade Messages
Message
The amount of
system memory has
changed.
This system does
not support
processors greater
than 95W.
Time-of-day clock
stopped.
Time-of-day not
set — please run
SETUP program.
Timer chip counter
2 failed.
TPM failure
(continued)
Causes
Faulty memory module.
Unsupported processor(s)
installed.
Faulty battery; faulty blade
board.
Incorrect Time or Date
settings; faulty blade board
battery.
Faulty blade board.
A Trusted Platform
Module (TPM) function
has failed.
Corrective Actions
See "Troubleshooting Blade
Memory" on page 297. If the
problem persists, see
"Getting Help" on page 337.
Replace the processor(s)
with a supported version.
See "Processors" on
page 225.
See "Troubleshooting Blade
Memory" on page 297. If the
problem persists, see
"Getting Help" on page 337.
Check the Time and Date
settings. See "Using the
System Setup Program
and UEFI Boot Manager" on
page 127. If the problem
persists, see
"Troubleshooting the
NVRAM Backup Battery" on
page 302.
See "Getting Help" on
page 337.
See "Getting Help" on
page 337.
About Your System
121

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents