Installing the LOM Riser Card
1 Remove the blade. See "Removing a Blade" on page 145.
2 Open the blade. See "Opening the Blade" on page 149.
3 Install the Network Daughter Card:
Lower the card into place until the card connector fits into the
a
corresponding connector on the system board. See Figure 3-34.
Secure the card with the three screws.
b
4 Tighten the screws to secure the card to the system board. See Figure 3-34.
5 Close the blade. See "Closing the Blade" on page 159.
6 Install the blade. See "Installing a Blade" on page 148.
Expansion Cards and Expansion-Card Riser
(PowerEdge M610x Only)
Expansion Card Installation Guidelines
Your system supports up to two Generation 2 PCIe expansion cards installed
in the connectors on the expansion-card riser. To locate the expansion-card
connectors on the expansion-card riser, see Figure 3-38.
•
The expansion slots support full-height, full-length, single- or double-
width cards.
•
Each expansion card can have a power consumption of up to 250 W.
NOTE:
If only a single PCIe expansion card is installed, it can have power
consumption up to 300 W.
•
Both the expansion slots are x16 connectors.
•
Do not install an expansion card in slot 2 if a double-width card is installed
in slot 1.