Table 1-26. Blade Messages
Message
Memory set to
minimum frequency.
Warning! A fatal
error has caused
system reset.
Please check the
event log for
details.
Warning! Following
faulty DIMMs are
disabled: DIMMxx,
DIMMyy.
Warning! No
microcode update
loaded for
processor n.
Warning: The
current memory
configuration is
not validated.
Change it to the
recommended memory
configuration or
press any key to
continue.
(continued)
Causes
The memory frequency
may be intentionally set
lower for power
conservation.
The current memory
configuration may support
only the minimum
frequency.
Unspecified error.
Faulty or improperly
seated memory modules.
Unsupported processor.
There is no memory
configuration error, but
the memory configuration
is not recommended by
Dell.
Corrective Actions
If not an intentional setting,
check any other system
messages for possible causes.
Ensure that your memory
configuration supports the
higher frequency. See
"System Memory" on
page 159.
Check the system event log
for information about the
error.
See "Troubleshooting Blade
Memory" on page 297.
Update the BIOS firmware
using the Dell Support
website at support.dell.com.
See "System Memory" on
page 159.