Table 6-8 Informational Codes (Continued)
Event code Event code name
0x6E2
Front End Fibre Loop
Error
0x6E3
Fibre Channel Initiator
Gone
0x6E4
Fibre Channel Loop
Down
0x6E5
Fibre Channel Loop Up
0x6E6
Fibre Channel Loop
Timeout
0x6E7
Fibre Channel LIP
Timeout
0x6E8
Fibre Channel Link Up
Timeout
0x6E9
Front End Fibre Loop
Event
Table 6-9 Thresholded (Soft) Codes
Event code Event code name
0x801
Soft SCSI Error
0x802
Illegal SCSI Bus
Interrupt
0x803
Recommend Disk
Replacement
0x804
Single Bit Error
6-44
Unsolicited Event Log
Description
The SP's fibre loop failed to initialize.
The SP tried to communicate with an initiator that is no longer
responding.
A loop down was detected. This is a normal occurrence
followed by a loop up during loop initialization.
The fibre loop is up and ready for communication.
An internal timeout has occurred in the fibre channel interface.
The SP will wait for the condition to clear and then resume
operation.
The Fibre Channel interface timed out during loop
initialization. The SP will continue taking action to bring the
link completely up.
The Fibre Channel interface timed out waiting for the link to
come up. The SP will continue taking action to bring the link
completely up.
Front End fibre loop error message threshold exceeded.
Description
An abnormal SCSI bus or disk drive
event was detected. A retry of the
operation cleared the condition.
An inconsistent interrupt situation has
been detected on the SP.
The disk module has sent status to the
SP indicating that the disk may be
susceptible to a fault in the near future.
(IBM disk modules only.)
The SP's tolerance level for single bit
errors in the write cache has been
exceeded.
Recommended
threshold
Notify the user after 25
errors per day per FRU.
Notify the user after 10
errors per month per
FRU.
Replace the disk module.