Table 6-10 Error Codes
Event code Event code name
0x901
Hard SCSI Error
0x903
Fan Removed
0x904
VSC Removed
0x905
Chassis
Overtemperature
0x906
Unit Shutdown
0x907
Controller Firmware
Panic
0x908
Hardware Fault - Cache
Disabling
0x909
Cache Dump Failed
0x90A
Assign Fails - Cache
Dirty Unit
0x90B
Controller Cannot
Initialize Cache
0x90C
Cache Image Exceeds
Memory Size
0x90D
BBU Removed
0x90E
BBU Failed
0x90F
Cache Recovered With
Errors
6-46
Unsolicited Event Log
Description
An abnormal SCSI bus or disk drive event was detected and
could not be cleared through retry operations.
A fan pack has been shut down or removed from the system.
A VSC (power supply unit) has been shut down or removed
from the system.
A chassis overtemperature condition has been detected, and
the SP will attempt corrective action.
The logical disk unit of which this disk module is a member
has been shut down and can no longer be accessed by the
host.
A fatal firmware (SP microcode) error occurred; as a result, the
microcode reloaded and restarted the SP. This message is
logged after the restarted session completes its initialization.
Some hardware condition has caused the SP to disable the
cache. The problem might be:
• BBU is not ready (not present and fully charged)
• One or more vault disks is missing or being rebuilt
• Fan fault occurred
• SP failed
A fault occurred but the SP cannot dump the cache to the
vault drives, most likely because two or more cache vault
disks are missing or have failed.
The SP cannot assign this unit, because it is marked as
having cached data outstanding, and the controller has no
access to the data.
A hardware or software failure occurred when the SP
attempted to initialize a new cache image.
This SP is incapable of loading the saved cache data image
due to insufficient cache memory size.
The Battery Backup Unit in this disk array has failed or been
removed.
The Battery Backup Unit in this disk array has failed its
internal self-test.
A nonmirrored cache recovery was attempted but failed to
recover the cache pages for some cached LUNs. It does not
apply to a disk array with two SPs.