Quick Start To Nec Display Wall Calibrator - NEC KT-X46UN User Manual

Table of Contents

Advertisement

 | NEC Display Wall Calibrator - UsEr's GUiDE
5
Quick start to NEC Display Wall Calibrator
1. Install Software
Install the NEC Display Wall Calibrator software on the host PC. The serial number provided on either the CD-ROM
cover, or with your purchase will be required to install the software.
2. Connect color sensor
Connect the color sensor to a USB port on the host PC and verify the drivers are installed correctly.
3. Warm up displays
Power-on each of the displays in the video wall. The displays should be warmed up for at least 30 minutes before
calibrating.
4. Configure and connect displays
It is not necessary to connect the video output from the PC to any of the displays. The only connection to the
displays will be either RS232 and/or LAN (Ethernet). Wireless LAN can also be used from the host PC if using a
wireless access point or router.
See chapter 3 for detailed information about the various connection configurations.
5. Define Video Wall Layout and Connections
Use the "Layout Wizard" from the Edit menu to specify the number of displays, their layout, calibration order, and
connection method.
If necessary modify the connection settings for any display by using the Connection panel.
6. Verify Communications
Test the communications to all the displays by clicking the Verify All button on the Actions panel. This will attempt to
communicate with each display in the layout.
If there is an error in verifying communications with a display, see the troubleshooting guide in chapter 7:
As each display is successfully tested, it's rectangle in the main window will change from Yellow to Cyan. Once all
displays are verified, it is possible to continue on with the next stage of the calibration process.
7. Initialize Display Settings
Click the Initialize All button on the Actions panel to reset the color settings on each display to the default state.
8. Measure displays with default settings
If Maximum Possible Matching is selected as the Intensity adjustment method in the current Calibration Target, it