7.2. "CURRENTSOURCE" Control procedure
7.2.1. Current Source Control
CMD
Data1
Command
Target
(0xF5)
(0x88)
Command (0xF5) : Start bit
Target (0x88) : Set bit
Monitor ID (0x00) : Default value -> 0x00
CMD (0xFE) : command data
Parameter(0x01) : ' Current Source ' parameter
Value : Data value
0 : AV1
1 : AV2
2 : AV3
6 : COMPONENT
9 : DVI
10 : DSUB
7.2.2. Current Source state read
CMD
Data1
Command
Target
(0xF4)
(0x89)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x01) : 'Current Source' parameter
CMD
Data1
Command
Value
(0xF1)
Command (0xF1) : Start send bit
Value : Current Source getting value
0 : AV1
1 : AV2
2 : AV3
6 : COMPONENT
9 : DVI
10 : DSUB
Data2
Data3
Monitor ID
CMD
(0x00)
(0xFE)
Data2
Data3
Monitor ID
CMD
(0x00)
(0xFE)
Data4
Data5
Parameter
Value
(0x01)
Data4
Parameter
(0x01)