" CURTEMP_MAIN " Control procedure
7.43.
7.43.1. Current main Temperature state read
CMD
Data1
Command
Target
(0xF4)
(0x89)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x37) : 'CURTEMP_MAIN ' parameter
CMD
Data1
Command
Value
(0xF1)
Command (0xF1) : Start send bit
Value : Current Temperature getting value
" CURTEMP_AUX " Control procedure
7.44.
7.44.1. Current aux Temperature state read
CMD
Data1
Command
Target
(0xF4)
(0x89)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x38) : 'CURTEMP_AUX ' parameter
CMD
Data1
Command
Value
(0xF1)
Command (0xF1) : Start send bit
Value : Current Temperature getting value
Data2
Data3
Monitor ID
CMD
(0x00)
(0xFE)
Data2
Data3
Monitor ID
CMD
(0x00)
(0xFE)
Data4
Parameter
(0x37)
Data4
Parameter
(0x38)