" RF_SHARPNESS " Control procedure
7.14.
7.14.1. Sharpness Control (AV , S-video , Component mode)
CMD
Data1
Command
Target
(0xF5)
(0x88)
Command (0xF5) : Start bit
Target (0x88) : Set bit
Monitor ID (0x00) : Default value -> 0x00
CMD (0xFE) : command data
Parameter(0x0D) : ' RF_SHARPNESS ' parameter
Value: 0 ~ 100 (range)
7.14.2. Current Sharpness state read(AV , S-video , Component mode)
CMD
Data1
Command
Target
(0xF4)
(0x89)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x0D) : 'RF_SHARPNESS ' parameter
CMD
Data1
Command
Value
(0xF1)
Command (0xF1) : Start send bit
Value : Current RF_SHARPNESS getting value
0 ~ 100 (range)
Data2
Data3
Monitor ID
CMD
(0x00)
(0xFE)
Data2
Data3
Monitor ID
CMD
(0x00)
(0xFE)
Data4
Data5
Parameter
Value
(0x0D)
Data4
Parameter
(0x0D)