Chapter 5
HP DiagTools then reports whether the Basic System Test was passed.
Record the hardware inventory and the Basic Test results by creating a
Support Ticket text file.
NOTE
To create a Support Ticket, refer to the HP NetServer
DiagTools Error Reference and User Guide, and write the
Support Ticket to a flexible diskette.
If the Basic System Test was passed, the upgrade has been verified.
Do the following:
a. Press the F3 function key to exit HP DiagTools.
b. Remove the flexible diskette from the drive.
c. Go to the section "Reinstall the NOS."
If the Basic System Test was failed, do the following:
a. View the Support Ticket as described in the HP NetServer
DiagTools Error Reference and User Guide.
b. Look for error messages, and note their error codes.
c. Determine the corrective actions for each error code, as listed in
the HP NetServer DiagTools Error Reference and User Guide.
d. Press the F3 function key to exit HP DiagTools.
e. Refer to Chapter 3 or 4 to shut down the NetServer, disconnect it,
and take the corrective actions listed in the HP NetServer
DiagTools Error Reference and User Guide.
f. Replace all covers as described in Chapter 3 or 4. Reconnect the
NetServer, and restart it with the HP DiagTools flexible diskette in
the drive.
g. Run the Basic System Tests again.
h. If the Basic System Test was failed, go to Step 6.
i. If the Basic System Test was passed, the upgrade has been
verified. Create a Support Ticket, and write it to a flexible diskette.
Press the F3 function key to exit HP DiagTools. Remove the
flexible diskette from the drive. Go to the section "Reinstall the
NOS."
52
Verification