Specifications

Operating Temperature
Non-operating
Temperature
Operating Humidity
Non-operating Humidity
Operating Altitude
Non-operating Altitude
Minimum Clearance
Front
Sides
Top
Back
Weight and Dimensions
Height
Width
Depth
Weight
Weight and Dimensions LH 3r
Height
Width
Depth
Weight
Power supply
input voltage
Power supply output
Sound pressure (LpA)
102
5 to 35 C (41 to 95 F)
-40° to +65° C (-40° to +149° F)
20% to 80% relative humidity, non-condensing
5% to 95% relative humidity, non-condensing
-30 to 3,000 m (~10,000 ft)
-30 to 12,000 m (~40,000 ft)
1 m (39 in)
2.5 cm (1.0 in)
2.5 cm (1.0 in)
15 cm (6.0 in)
LH 3
494.8 mm (19.5 in)
350.5 mm (13.8 in)
724.2 mm (28.5 in)
35 - 50 kg (77 - 110 lb)
NOTE
A fully-loaded NetServer can weigh up to 160 pounds (73 kg).
Follow local safety regulations, and use one person for every 40
pounds (18 kg) of NetServer weight when lifting it.
354.7 mm (14 in)
482.6 mm (19 in)
749.2 mm (29.5 in)
35 - 50 kg (77 - 110 lb)
NOTE
A fully-loaded NetServer can weigh up to 160 pounds (73 kg).
Follow local safety regulations, and use one person for every 40
pounds (18 kg) of NetServer weight when lifting it.
Auto-Ranging Power Supply
100 to 127 VAC at 50/60 Hz
200 to 240 VAC at 50/60 Hz
90 to 132 VAC at 47 - 63 Hz
180 to 264 VAC at 47 - 63 Hz
550 W maximum (per module)
55 dB(A), bystander position