Chapter 9 Messages
9.2 Command Messages
STXV0312 WARNING Backup has not started.
[Meaning]
Backup copying process has not started. The process is canceled.
[Action]
Check the copy status using "Backup status query command".
For details, refer to
STXV0313 ERROR Operations other than "stop" are not possible for this copy type.
[Meaning]
Operations other than "stop" are not possible for this copy type. The process is canceled.
[Action]
Check copy type and options for the specified copy set information, and try again.
STXV0314 ERROR Internal inconsistency.
[Meaning]
Internal inconsistency. The process is canceled.
[Action]
Refer to
"10.2 How to Obtain Error Information" (page
before contacting a Fujitsu field engineer (FE).
STXV0315 ERROR The specified physical disk number does not exist in the source
disk. Disk = ["physical disk number"]
[Meaning]
The specified physical disk number does not exist in the source disk. The process is canceled.
[Action]
Check the "physical disk number" of the source disk.
STXV0316 ERROR The -a option cannot be specified with this copy type. Type =
"copy type"
[Meaning]
The -a option cannot be specified with this copy type. The process is canceled.
[Action]
Check the option to be specified.
"8.5 Backup Status Query Command (stxvquery)" (page
108
ETERNUS VSS Hardware Provider 2.1 User's Guide
Copyright 2012 FUJITSU LIMITED
59).
131), and prepare the required information