Message
ID
KAPL01021-
E
KAPL01023-
W
KAPL01024-
W
8-10
Message Text
Cannot execute the HDLM command due
to insufficient memory.
The last Online path for the device cannot
be placed Offline(C).
The specified parameters cannot be
specified at the same time. Operation
name = aa...aa, parameters = bb...bb
Messages
Hitachi Dynamic Link Manager User Guide (for AIX(R))
Explanation
and then contact your
HDLM vendor or the
company for which
you have a service
contract. For details on
the DLMgetras utility,
see
DLMgetras Utility
for Collecting HDLM
Error Information on
page
7-4.
Details
Memory required for HDLM
command processing could
not be allocated.
Action
Terminate unneeded
applications to increase the
amount of free memory,
and then retry.
Details
The path specified in the
offline operation cannot
be placed in the
Offline(C) status because
it is the last path for the
applicable logical unit.
Action
Use the view operation of
the HDLM command
(dlnkmgr) to check the
status of the paths. For
details on the view
operation, see
view
(Displays Information) on
page
6-30.
Details
aa...aa:clear, offline,
online, set, or view
bb...bb:Parameters that
cannot be specified at the
same time
Action
Execute help operation of
the HDLM command
(dlnkmgr) to check which
parameters can be
specified at the same time,
and then retry. For details
on the help operation, see
help (Displays the