If an error occurs, you might have to set the error log collection level to 1 or
higher to collect any log information.
The higher this value is set, the more information that will be output. As the
amount of log information to be output increases, it will take less time to
overwrite the old error log information with the new information.
The following is an example of setting up the error log collection level by
using a command:
# /usr/DynamicLinkManager/bin/dlnkmgr set -ellv 2
Specify the error log collection level as a number.

Setting the Trace Level

The trace output level can be set.
You can set up the trace level for a trace file hdlmtrn.log (n indicates a file
number from 1 to 64).
Table 3-16 Values for the Trace Level Setting on page 3-73
describes the possible values for the trace level setting.
0
1
2
3
4
If an error occurs, you may have to set the trace level to 1 or higher to
collect any trace information.
The higher this value is set, the more information that will be output. As the
amount of trace information to be output increases, it will take less time to
overwrite the old trace information with the new information.
For normal operation, we recommend that you set the trace level to 0. If you
set the trace level to a value higher than necessary, HDLM performance
Value
All information for errors of the "Warning" level or higher is
collected.
All information for errors of the "Information" level or
higher is collected.
All information for errors of the "Information" level or
higher (including maintenance information) is collected.
Table 3-16 Values for the Trace Level Setting
Value
No trace is output.
Only error information is output.
Program operation summaries are output.
Program operation details are output.
All information is output.