iSM13715: Disk Arrays managed by iSM do not
exist. (code=<aaa...a>-<bbb...b>-
<bbb...b>-<bbb...b>)
[Classification]
ERROR
[Explanation]
Specified disk array does not exist.
aaa...a
bbb...b
[Measures]
Check disk array name and input a correct name.
iSM13716: State of specified Disk Array is not
'freeze'. (code=<aaa...a>-<bbb...b>-
<bbb...b>-<bbb...b>)
[Classification]
ERROR
[Explanation]
Specified disk array is under "defreeze" status.
aaa...a
bbb...b
[Measures]
Check the status of the disk array.
iSM13717: Control path is not set to iSM/Server.
(code=<aaa...a>-<bbb...b>-<bbb...b>-
<bbb...b>)
[Classification]
ERROR
[Explanation]
I/O path for disk array is not specified to use iSM server (replication
management function).
aaa...a
bbb...b
[Measures]
Specified option is available only when I/O path for disk array is specified to use
iSM server (replication management function).
Check environment settings of NEC Storage ReplicationControl.
: Process number
: Detailed information (This code isn't disorder reason but a value
for maintenance.)
: Process number
: Detailed information (This code isn't disorder reason but a value
for maintenance.)
: Process number
: Detailed information (This code isn't disorder reason but a value
for maintenance.)