NEC Storage Manager Messages Handbook page 356

Messages handbook
Table of Contents

Advertisement

iSM14402: Configuration released. : Disk
Array=<aaa...a>, status=<bbb...b>
[Classification]
INFO
[Explanation]
It indicates that configuration setting completed.
aaa...a
bbb...b
[Measures]
An error may have occurred on the disk array or the control path. Remove the
cause of the error, disconnect the iSM client from which configuration setting
was made, and connect the iSM client again.
iSM14403: LD bind : LDN=<aaaa>h, <aaaa>h,...
RANK=<bb>h, <bb>h,... PDG=<cc>h,
status=<ddd...d>
[Classification]
INFO
[Explanation]
It indicates that the binding of Logical Disk was executed.
aaaa
bb
cc
ddd...d
[Measures]
When an error occurs (status=failed was output), the configuration or setting of
the disk array may be changed. After updating it to the newest information or
restarting state monitoring, check current state and execute again.
: Disk array name
: Execution state of the command.
good
: Normal
failed(xxxx) : Error occurred (xxxx is error description)
: Logical disk number
: RANK number
: PD group number
: Execution state of the command.
good
: Normal
failed(xxxx) : Error occurred (xxxx is error description)
351