Installation; System Preparation; Unpacking; Before Installing - NEC 1090030 - DSX Systems PHONE SuperDisp Phone BLAC Hardware Manual

Hardware manual
Hide thumbs Also See for 1090030 - DSX Systems PHONE SuperDisp Phone BLAC:
Table of Contents

Advertisement

System Preparation

System Preparation

Unpacking

Unpack the equipment and check it against your equipment lists. Inspect for physical damage. If you are not
sure about a component's function, review Components (page 1). Contact your Sales Representative if you
have additional questions.
Have the appropriate tools for the job on hand, including: a test set, a punch down tool and a digital voltmeter.

Before Installing

Make sure you have a building plan showing the location of the common equipment, extensions, the telco
demarcation and earth ground. In addition, the installation site must meet the requirements outlined in the
Standard Practices Manual.

Site Requirements

The common equipment is contained in the wall-mounted Main Equipment Cabinet. Choose a central location
for the cabinet that allows enough space for the equipment — and provides enough room for you to comfortably
work. Figure 1: Installation Layout, DSX-40 (page 20) and shows you about how much space your system
requires.

Single Line Telephone REN Limitations

Please note the following when installing single line telephones:
The total Ringer Equivalence Number (REN) per system cannot exceed 10.
The total REN per analog port cannot exceed 5.
Ringer Equivalence is cumulative.
A REN of 1 is the normal for an industry standard 2500 set with electromechanical ringer. Many phones
with electronic ringers have significantly lower RENs.
DSX-40 Hardware Manual

Installation

Installation ◆ 19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsx-40Dth-1-1Dtr-1-1Dtr-1hm-1Dsx cordless lite ii

Table of Contents