Pioneer PDP-502MX Manual page 137

Plasma display monitor
Hide thumbs Also See for PDP-502MX:
Table of Contents

Advertisement

3) <GST> (GET STATUS) – The status of various settings is transmitted in the following formats:
STX
PC SOFTWARE
(02 hex)
VERSION (5 Byte)
DUMMY DATA
(3 Byte)
CLAMP
(3 Byte) 4
MIRROR MODE
(3 Byte)
(NOTE) • Items not related to the ongoing INPUT functions/INPUT signals will output dummy data.
1 ........ Depending on the present signal input (video or PC signal) the output content will switch.
2 ........ Dummy data will be output unless in INPUT 1 or 2.
3 ........ Dummy data will be output unless in INPUT 1.
4 ........ Dummy data will be out put unless in INPUT 3 or 4.
• For more information concerning output, refer to section 5.5.4, "List of RS-232C Commands".
Temperature
TxD output value (3 bytes)
Outside air
temperature ( C) (see note)
(NOTE):
The term 'outside air temperature' as it is used here is meant to serve as a rough guideline for when the
unit has been installed so as to allow the free flow of air around the unit, and this term is therefore to be
distinguished from the term 'ambient temperature' as used in 3 "Installation". Note that there may be
times when errors occur in temperature readings. Also note that it is particularly important to be sure to
check the ambient temperature when the unit has been installed as described in 3.4 "Special Installation"
to ensure that all installation requirements have been satisfied.
4) GS2 (GET STATUS 2) - Outputs the state of the various settings in the format shown below.
STX
SUB VOLUME
(02 hex)
INPUT 1 (3 Byte)
G SIDE MASK
(3 Byte)
INPUT FUNCTION
COLOR MODE
(3 Byte)
(3 Byte)
COLOR SYSTEM
3D Y/C
(3 Byte) 2
(3 Byte) 3
ABL
DUMMY DATA
(3 Byte) 4
(3 Byte)
CENTRAL SCREEN
FAN CONTROL
BRIGHTNESS
FORMAT (3 Byte)
1
(3 Byte)
300
340
to 30.0
to 34.0
SUB VOLUME
SUB VOLUME
INPUT 2 (3 Byte)
INPUT 3 (3 Byte)
B SIDE MASK
DUMMY DATA
(3 Byte)
(3 Byte)
RS-232C Adjustment Mode
SCREEN SIZE
(3 Byte)
HIGH CONTRAST
INPUT SETTING
(3 Byte)
KEY LOCK
(3 Byte)
EASY TEMPERATURE
ACCUMULATED
MEASUREMENT
ON TIME (5 Byte)
(3 Byte)
380
420
to 38.0
to 42.0
to 45.0
SUB VOLUME
INPUT 4 (3 Byte)
DUMMY DATA
DUMMY DATA
(3 Byte)
POWER SAVE
(3 Byte) 1
(3 Byte) 4
OSD DISPLAY
(3 Byte)
ETX
(03 hex)
450
XXX
45.0 or more
R SIDE MASK
(3 Byte)
ETX
(3 Byte)
(03 hex)
137