JVC KM-H2500 Manual page 55

Hide thumbs Also See for KM-H2500:
Table of Contents

Advertisement

4.
Use the Bank knob to select a GPI bank
configured as GPI outputs.
5.
Press NEXT.
6.
Use the Pin knob to select which GPI output pin
to configure.
7.
Use the Type knob to select the GPI output level
and trigger type. You can choose from the
following:
• LowE — The GPI output level is set to low
and the trigger is set to edge.
• HighE — The GPI output level is set to high
and the trigger is set to edge.
• LowL — The GPI output level is set to low
and the trigger is set to level.
• HighL — The GPI output level is set to high
and the trigger is set to level.
8.
If you selected either LowE or HighE in the
previous step, use the Dur knob to set the length
(in frames) that the GPI output remains triggered.
Note:
• Edge triggered GPI outputs remain triggered for
the configured duration.
• Level triggered GPI outputs toggle between
latched and unlatched each time you press the
corresponding Wipe Pattern button.
• Changing the configuration of a GPI output pin that
is currently latched causes it to unlatch.
GPI Input Banks
Banks configured as GPI inputs have inputs assigned
as follows (Pin 1 is the top right pin when looking at
the GPI Port).
13 12 11 10
9
8
25
24
23
22
21
Figure 16 GPI Port
Table 13 GPI Port GPI Input Mapping
Pin
Bank 1
1
Dissolve Key 1
2
Dissolve Key 2
3
Dissolve Key 3 (KM-H 3000 only)
4
Perform Auto Transition
6
7
8
7
6
5
4
3
2
1
20
19
18
17
16
15
14
Trigger
Table 13 GPI Port GPI Input Mapping
Pin
5
Perform Program / Preset Bus cut
6
Perform Key 1 cut
7
Perform Key 2 cut
8
Perform Key 3 cut (KM-H 3000 only)
9
Perform Fade to Black
10
Set Aux Bus 1 to Input 1
11
Set Aux Bus 1 to Input 2
12
Set Aux Bus 1 to Input 3
13
Set Aux Bus 1 to Input 4
14
Set Aux Bus 1 to Input 5
15
Recall Memory 0
16
Recall Memory 1
17
Recall Memory 2
18
Recall Memory 3
19
Recall Memory 4
20
Recall Memory 5
21
Recall Memory 6
22
Recall Memory 7
23
Recall Memory 8
24
Recall Memory 9
Not Assigned to a Bank
25
Ground
a. Only memory registers from memory bank 0 can be recalled
with a GPI trigger.
Note:
• GPI input pin assignments are not
user-configurable.
For More Information on...
• port locations, refer to the section "Control Panel
Rear Connections Overview" on page 2
Triggering GPI Outputs
You can manually trigger GPI outputs by holding
down the NEXT button and then pressing a Wipe
Pattern button corresponding to the GPI output you
Trigger
Bank 2
a
a
Bank 3
a
a
a
a
a
a
a
a
49