(4) Temperature control at Energy Saving Mode
This equipment has the following two types of temperature control for saving energy and returns
to ready status to perform printing in each mode upon printing request.
The period of time from the printing request to this mode can be set in "Setting Mode (08)" or by
an administrator.
Administrator setting procedure:
[USER FUNCTIONS] button → [ADMIN] (input of administrator's password) → [GENERAL] →
[ENERGY SAVER]
Auto Power Save Mode (Setting Mode (08-205)):
When the printing is not performed in a specified period of time (default setting: 15 min.) after the
previous printing is completed, the equipment enters to Auto Power Save Mode to turn OFF the
IH coil.
Auto Shut Off Mode (Setting Mode (08-206)):
When the printing is not performed in a specified period of time (default setting: 60 min (e-STU-
DIO350), 90 min (e-STUDIO450)). after the equipment entered to Auto Power Save Mode, the
equipment then enters to Auto Shut Off Mode to turn OFF the IH coil.
Warmng-up
°C
200
Temperature
of fuser roller
IH col ON
0
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Ready
Durng prntng
Fig. 13-405
13 - 9
Auto Power Save Mode
Fxed tme ( 0-205 )
( IH col OFF )
Fxed tme ( 0-20 )
e-STUDIO350/352/353/450/452/453
FUSER UNIT / PAPER EXIT SECTION
Auto
Shut Off
Mode
OFF