(5) Remove 1 screw and take off the coil holder
on the rear side.
(6) Pull out the IH coil from the rear side.
[J] Fuser roller
(1) Take off the fuser unit cover
(
Chapter 13.7 [B]).
(2) Take off the paper exit unit
(
Chapter 13.7 [F]).
(3) Take off the IH coil (
(4) Push down the pressure levers on both
sides.
(5) Remove the E-ring and gear A on the rear
side. After that, remove C-ring, gear and
bushing in order.
(6) Remove 2 screws and take off the coil
holder on the front side.
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Chapter 13.7 [I]).
13 - 21
Fig. 13-721
Fig. 13-722
Bushing
Pressure
lever
Fig. 13-723
Fig. 13-724
e-STUDIO350/352/353/450/452/453
FUSER UNIT / PAPER EXIT SECTION
Gear A
C-ring
Gear
13