Communication Parameters For Ccl003Z - Toshiba TOSVERT VF-S15 series Function Manual

Tosvert vf-s15 series cc-link option unit
Hide thumbs Also See for TOSVERT VF-S15 series:
Table of Contents

Advertisement

5.2.

Communication parameters for CCL003Z

Title
Communication error detection
c100
delay time
c101
Inverter operation at the
communication loss action
Preset speed
c102
operation selection
c103
Communication time-out
condition selection
CC-Link station number
c120 *
selection
CC-Link baud rate selection
c121 *
CC-Link extended selection
c122 *
* Set parameters according to the CC-Link network system.
Function
0.0 - 100.0 sec.
0: Stop and controlled by cmod, fmod
1: Operation continue
2: Deceleration stop
3: Coast stop
4: Network error stop (err8 trip)
5: Preset speed operation (by c102 setting)
0: None
1 to 15: Preset speed
0: Disconnection detection
1: When communication mode enable (Both cmod and
2: 1 + Driving operation
1 to 64
Set the number of stations of inverters (Remote device
station).
0: 156kbps
1: 625kbps
2: 2.5Mbps
3: 5Mbps
4: 10Mbps
Set the baud rate for CC-LINK network
0: Occupies one station (V1.10)
1: Occupies one station double (V2.0)
2: Occupies one station quadruple (V2.0)
3: Occupies one station octuple (V2.0)
The function of remote registers can be enhanced.
Description
fmod are set CANopen or communication option) only
- 13 -
E658130