6.1.

Program example for reading the inverter status

Example 1 shows a ladder logic to read the inverter status.
Y30 of the output unit is turned on when inverter of station 2 is forward running
X0
X0F
M0
X1020
Example
Remote input
RX0 to RXF
Station1
RX10 to RX1F
RX20 to RX2F
Station 2
RX30 to RX3F
X0:
Module error
X1:
Host data link status
X0F:
Module ready
SW80.1: Station 2 ready
SW80.1
X1
b15
0
0
0
0
1
Inverter status
b0: Forward running
b1: Reverse running
b2: Output terminal 1
b3: Output terminal 2
b4: Output terminal 3
b5: Failure FL
b6: PI control OFF
b7: Acceleration/deceleration pattern selection (1 or 2)
b8: Emergency stop
b9: Coast stop
b10: Alarm
( M0 )
Check the ready of the station 2
Turn on the relay of output
( Y30 )
unit (Y30)
[END]