3.3.1.3
Guided Configuration
The guided configuration mode allows a logical drive to be created by specifying setting items
sequentially.
The setting procedure is described below.
1. Click [Guided Configuration] in the [Mode Selection] of the Configuration Wizard.
2. Select [Redundancy] and [Existing Arrays] options and specify the number of logical
drives to be created in [Desired Number of Virtual Disks]. Click [Next].
Redundancy
[Redundancy Only]:
Create redundant array configuration.
[Redundancy when possible]:
Try to create redundant array configuration. If not possible, creates non-redundant
array configuration.
[No Redundancy]:
Create non-redundant array configuration.