216
FAILED Test:
221
NVRAM is corrupt; reinitializing
222
NVRAM mismatch occurred
223
Link lost on SAS wide port:
Allowed error rate exceeded on
225
SAS port:
Bad block reassigned:
226
Temperature sensor differential
228
detected on enclosure:
Disk test cannot start. No
229
qualifying disks found
Time duration provided by host
230
is not sufficient for self check
Firmware download failed on
235
enclosure:
Drive is not certified:
236
PDs missing from configuration
238
at boot
VDs missing drives and will go
239
offline at boot
VDs missing at boot
240
Previous
241
completely missing at boot
PD rebuild not possible as
245
SAS/SATA is not supported in
an array
VD
is
now
250
DEGRADED
VD is now DEGRADED
251
VD is now OFFLINE
252
VD disabled because RAID-5 is
254
not supported by this RAID key
VD disabled because RAID-6 is
255
not supported by this controller
VD disabled
256
drives are not supported by this
RAID key
PD missing
257
The test detects an error. Take the
replacement of the disk array controller into
account.
If the error occurs frequently, take the
preventive replacement of the disk array
controller into account.
If the error occurs frequently, take the
preventive replacement of the disk array
controller into account.
If the error occurs frequently, take the
preventive replacement of the disk and disk
array controller into account.
If the error occurs frequently, take the
preventive replacement of the disk and disk
array controller into account.
If the error occurs frequently, take the
preventive replacement of the disk into
account.
If the error occurs frequently, take the
preventive replacement of the enclosure into
account.
If the error occurs frequently, take the
preventive replacement of the disk into
account.
If the error occurs frequently, take the
preventive replacement of the disk array
controller into account.
If the error occurs frequently, take the
preventive replacement of the enclosure into
account.
Check the disk connection.
Check the disk connection.
Check the disk connection.
Check the disk connection.
configuration
Check the disk connection.
Check whether physical drives to be
supported are used.
PARTIALLY
Partial degrading is detected. Replace the
defected physical drive and run the rebuild
operation.
The logical drive is degraded. Replace the
defected physical drive and run the rebuild
operation.
The logical drive enters into the offline
status. Recover the data by using the
backup.
Please check the RAID key.
Please check the RAID key.
because SAS
Please check the SAS driver and the RAID
key.
Check the disk connection.
CAUTIONS AND RESTRICTIONS 73

Advertisement