Network --Setdns [--Suffix <Dns Suffix>] [--Primary <Ip Address>] [--Secondary <Ip Address>]; Network --Setbonding [--Mode <Alb | 802.3Ad>] [--Mtu <Supported Mtu Range 512 - 9000>] - Dell PowerVault Storage Area Network Reference Manual

Dell dr series system command line reference guide
Hide thumbs Also See for PowerVault Storage Area Network:
Table of Contents

Advertisement

Syntax
network --setstatic_ip --ip 10.20.20.20 --netmask 255.255.222.0 --gateway
10.25.20.10
Result
Bond device operation successful. Please run 'network --restart' for the
changes to take effect.
network --setdns [--suffix <dns suffix>] [--primary <ip address>] [--secondary <ip
address>]
Description
Configures the domain name system (DNS) for a DR Series system, which includes the corresponding DNS suffix and a
primary name server IP address (and optionally, a secondary name server IP address).
Syntax
network --setdns --suffix storage.local --primary 10.25.20.21 --secondary
10.25.20.25
network --setbonding [--mode <ALB | 802.3ad>] [--mtu <supported MTU range 512 - 9000>]
Description
Configures or updates the bonding mode or sets the maximum transmission unit (MTU) number to use for a DR Series
system.
Syntax
network --setbonding --mode ALB --mtu 1750
Result
Bond device operation successful. Please run 'network --restart' for the
changes to take affect.
NOTE: ALB load balancing does not balance the load properly when the backup servers are on a remote subnet.
This is because ALB uses the address resolution protocol (ARP) and ARP updates are subnet-specific. Because of
this, ARP broadcasts and updates are not sent across the router. Instead, all traffic is sent to the first interface in
the bond. To resolve this ARP-specific issue, make sure that the data source systems reside on the same subnet as
the DR Series system.
NOTE: When setting or changing the MTU value, make sure to verify that the Ethernet network switch is capable of
supporting an MTU size that is equal to or larger than the value being set. Any mismatch in MTU values between
the clients, the Ethernet network switch, and the DR Series system will make it inoperable. The relationship of
jumbo frames to MTU is discussed in this topic.
NOTE: When using the DR Series system CLI --setbonding and --mtu commands, a warning dialog displays with the
following message:
Incorrectly setting the MTU size will cause the DR4000 to not respond. You will
need to log in
to the system console and use the network --setbonding --mtu 1500 command to
resolve the
issue. Please verify that the switch is enabled and capable of supporting an
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents